Commentary: Ultra-Congruent Versus Cruciate-Retaining Inserts in Bilateral Simultaneous Total Knee Arthroplasty - A Randomized Controlled Trial
Kushagra Pathak1, Sahil Batra1*, Rajesh Malhotra2,3
1Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
2Clinical Lead and Senior Consultant Orthopaedics, Indraprastha Apollo Hospitals, New Delhi, India
3Former Head of the Department of Orthopaedics, AIIMS, New Delhi, India
Abstract
Insert selection in total knee arthroplasty (TKA) increasingly targets high-end satisfaction rather than basic function alone. Ultra-congruent (UC) bearings increase conformity to enhance anteroposterior stability and may substitute for variable posterior cruciate ligament behavior without a post-cam mechanism. In a recent Level I prospective bilateral contralateral randomized trial, Pathak et al. compared UC and cruciate-retaining (CR) inserts within the same patient undergoing bilateral simultaneous TKA using the Forgotten Joint Score-12 (FJS-12) as the primary endpoint. UC knees achieved statistically higher FJS-12, whereas legacy patient-reported outcome measures (Oxford Knee Score and Knee Society Score), radiographic measures, gait-laboratory outcomes, and clinical stability surrogates were similar. This pattern should be interpreted cautiously. First, FJS-12 is less prone to ceiling effects and may detect subtle patient-perceived differences that other measures miss. Second, commonly invoked mechanistic explanations - improved anteroposterior stability, greater mid-flexion confidence, and better performance in transitional tasks - remain hypotheses rather than proven causal pathways in the index trial. Third, although the trial is methodologically elegant, it remains limited by sample size, two-year follow-up, single-surgeon/single-center execution, and the external-validity constraints and perception biases inherent to bilateral simultaneous TKA. The broader literature still supports short- to mid-term equivalence of UC and CR/posterior-stabilized designs in most clinical and objective outcomes, with implant-specific survivorship data generally reassuring for UC. Current findings therefore argue more strongly for better outcome measurement than for routine superiority claims. Future work should link joint-awareness PROMs with task-specific biomechanics, prespecified subgroup analyses, and longer-term implant-family surveillance.
Where are we now?
Total knee arthroplasty (TKA) reliably relieves pain and restores basic function, yet a meaningful minority of patients remain dissatisfied or remain conscious of the reconstructed joint in daily life despite technically well-executed surgery1-4. In contemporary arthroplasty practice, success is therefore no longer defined only by pain relief or acceptable walking ability. Increasingly, the challenge is to discriminate among good, very good, and excellent results. The Forgotten Joint Score-12 (FJS-12) was developed around this problem: it measures joint awareness, has lower ceiling effects than several legacy instruments in well-performing cohorts, and may therefore be better suited to detect subtle between-design differences in high-functioning patients5-8. Published interpretation tools provide important context, with reported FJS thresholds including a minimal clinically important difference (MCID) of 13.7 points9,10.
Insert choice sits at the center of this high-end satisfaction problem. CR designs attempt to preserve posterior cruciate ligament (PCL) function and native rollback, but they depend on reproducible PCL competence and balancing. UC designs increase conformity to provide intrinsic anteroposterior stability without the additional box preparation and post-cam mechanism of many posterior-stabilized (PS) constructs11,12. Conceptually, UC occupies a middle ground between CR and PS: it aims to reduce dependence on variable biologic restraint while avoiding the mechanical features specific to PS knees.
The index randomized controlled trial (RCT) recently examined this philosophy using an elegant design: a prospective, randomized, blinded, within-patient bilateral trial in which each patient received a UC insert in one knee and a CR insert in the contralateral knee, with FJS-12 as the primary outcome. UC knees showed statistically higher FJS-12 across follow-up, with the greatest separation at 12 months, and an MCID of 5.7; though the caveat being MCID thresholds are defined for unilateral knee, and need further research for Bilateral simultaneous TKA. There were no significant between-design differences were seen in legacy PROMs, radiographic parameters, gait-laboratory measures, or clinical stability surrogates13. The strengths of this design are substantial. By comparing both inserts in the same host, the study minimizes confounding from age, sex, comorbidity burden, pain threshold, rehabilitation environment, and baseline activity profile.
At the same time, the limitations must be acknowledged; which include the small size of the cohort, limited follow-up of two years and the trial reflecting a single-surgeon/single-center experience. No doubt the bilateral simultaneous approach is a powerful way to isolate insert-related differences, but it introduces its own biases. Direct comparison of knees by patients tends to magnify subtle experiential differences or create perception bias independent of meaningful functional separation14. Also, factors like limb dominance, asymmetric postoperative pain, side-specific rehabilitation, and cross-comparison effects may influence preference or joint awareness. Further, bilateral simultaneous TKA patients comprise a small cohort and may not represent the broader unilateral TKA population mostly encountered. These issues do not negate the trial's value; rather, they define the boundaries of inference and should be acknowledged accordingly.
These findings should also be placed within the broader UC literature rather than interpreted in isolation. A recent systematic review and meta-analysis concluded that most short-term comparative studies do not show a consistent clinical advantage of UC over CR or PS inserts and emphasized the need for longer-term, more standardized comparisons15. At the same time, registry-linked survivorship data within a single implant family suggest no excess revision risk for UC relative to CR and, in some comparisons, lower revision risk than PS in selected systems16. Other cohort studies likewise report satisfactory mid- to long-term survivorship of anterior-stabilized or UC bearings in selected implant families17. Importantly, implant-specificity matters as well; outcomes from one UC platform cannot be generalized automatically to all conforming inserts. A recent bilateral preference study illustrates this point and also tempers any sweeping claim of superiority; at a mean follow-up of 5.4 years, 50% of patients had no preference between knees, 26% preferred the CR knee, and 24% preferred the highly congruent knee14. The totality of available evidence therefore suggests that any advantage of UC, if present, is likely modest, context-dependent, and potentially system-specific and not universal.
Where do we need to go?
The first important step is to focus on each secondary parameter separately, rather than grouping heterogenous outcomes under the broad term ‘objective metrics. The Oxford Knee Score is a legacy PROM; the Knee Society Score mixes patient report and clinician-rated domains; radiographic alignment is a structural descriptor; gait-laboratory outputs are controlled biomechanical measurements; and stability (static and dynamic) are simplified clinical proxies. Each of these construct answers a different question. A more precise reading of the index RCT is that statistically higher joint awareness scores occurred despite similar legacy PROMs, similar radiographic findings, similar steady-state gait-laboratory outputs, and similar clinical stability surrogates13.
Published thresholds such as the MCID, minimal detectable change, and PASS are useful anchors for judging relevance, but they were derived primarily for patient-level longitudinal change or for absolute postoperative states, not for side-to-side comparisons between two knees in the same patient9,10. Accordingly, a statistically significant between-knee difference in FJS-12 should not automatically be equated with clinically important superiority. It is more defensible to state that the index RCT demonstrated a statistically higher patient-reported joint-awareness score in UC knees, at the same time the clinical importance of that difference at the individual-patient level remains uncertain.
Now the question is why were there no significant differences in objective parameters? One plausible explanation is that conventional gait protocols emphasize steady-state level walking, whereas joint awareness is more often triggered by transitional or high-demand situations such as stair negotiation, turning, pivoting, uneven terrain, or fatigue states18,19. Another plausible explanation is that conformity-based UC geometry may reduce sensitivity to subtle PCL imbalance and mid-flexion anteroposterior instability that patients can feel even when standard laxity tests or force-plate analyses appear similar20-22. However, the index RCT did not directly measure fluoroscopic kinematics, dynamic anteroposterior laxity during demanding tasks, fatigue-state behavior or perturbation responses13. These explanations therefore remain biologically plausible hypotheses rather than established mechanisms.
Finally, any notion of UC benefit must be balanced against possible tradeoffs. Historical concerns around more conforming polyethylene inserts have included pitting, delamination, and fatigue-related material failure, particularly with older polyethylene formulations and under adverse loading conditions23,24. From a tribological perspective, the potential advantage of UC inserts should not be interpreted solely in terms of constraint. Greater articular conformity may reduce peak contact stress and thereby theoretically limit focal damage such as pitting or delamination. However, the larger contact area may also increase the sliding interface and raise concerns regarding volumetric polyethylene wear. Modern highly cross-linked polyethylene appears to mitigate some of these concerns, with registry data suggesting comparable or improved revision performance compared with conventional polyethylene, particularly for wear and loosening25. Contemporary material processing and implant-specific registry data are no doubt reassuring with the currently available comparative studies do not demonstrate a clear survivorship penalty for UC in selected systems15,16. Even so, the absence of a short-term penalty is not equivalent to proof of long-term equivalence across all implant families. Hence, there is a need for a more cautious interpretation of superiority of UC over CR inserts.
How do we get there?
In our view, three pragmatic directions can move the field forward. First, comparative insert studies should align objective testing with the lived experience of TKA. Future protocols should incorporate day-today task-specific biomechanics including stairs, slopes, sit-to-stand under speed or fatigue, turning, pivoting, perturbation testing, and uneven-surface walking. These should be paired with joint-awareness PROMs such as FJS-12. Wearable inertial sensors and ecologically valid activity monitoring may help bridge the gap between gait-laboratory measurements and daily function26,27. Also, instrumented gait analysis, fluoroscopy, or marker-based motion analysis should prioritize tibial axial rotation, anterior tibial translation, flexion-extension coupling, stance-phase stability, and side-to-side symmetry during demanding tasks such as stair negotiation, pivoting, turning, sit-to-stand transitions, and rapid direction change. These parameters will better capture the dynamic constructs that influence whether a replaced knee feels ‘forgotten’ during routine activity.
Second, the next question is not simply whether one insert is better on average, but which patient may benefit from which insert. The most likely explanation for a modest average FJS advantage is effect heterogeneity. Potentially informative subgroups include knees in which CR balancing is less predictable, such as those with marked coronal deformity, high flexion contracture, large preoperative laxity, inflammatory synovitis, or specific alignment phenotypes. A good example would be the constitutional varus knee with borderline PCL behavior, in which a more conforming insert might plausibly improve perceived confidence; however, this remains a prespecified hypothesis to be tested rather than a recommendation supported by the current trial. Registry-linked analyses and randomized studies with predefined subgroup hypotheses are the most efficient way to address this question28.
Third, longer-term surveillance remains essential. Early patient-perceived benefit should persist without later compromise in polyethylene durability, kinematic behavior, noise, loosening, or revision. Implant-family-specific registry analyses, comparative cohort studies, and long-term randomized follow-up are therefore mandatory15,16,29,30. At present, the strongest immediate implication of the index RCT is methodological rather than prescriptive: if our goal is for patients to "forget" their knee, we must measure that construct directly and test it under conditions that actually make knees memorable13.
Conclusion
In the index bilateral randomized trial, UC inserts had statistically higher FJS-12 than CR inserts, while legacy PROMs, radiographs, gait-laboratory outputs, and clinical stability parameters were similar13. What is suggested, but not proven, is that FJS-12 may be more sensitive than traditional measures to subtle, patient-perceived design differences and that UC conformity may improve confidence during demanding tasks. The question remains whether this change is clinically important at the individual-patient level, whether it generalizes beyond bilateral simultaneous TKA and beyond specific implant systems, and whether any early joint-awareness benefit persists without long-term tradeoffs. For now, these data should refine how success is measured after TKA more than they should dictate routine insert selection in primary practice.
References
- Bourne RB, Chesworth BM, Davis AM, et al. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res. 2010; 468(1): 57-63. doi:10.1007/s11999-009-1119-9
- Gunaratne R, Pratt DN, Banda J, et al. Patient dissatisfaction following total knee arthroplasty: a systematic review of the literature. J Arthroplasty. 2017; 32(12): 3854-3860. doi:10.1016/j.arth.2017.07.021
- DeFrance MJ, Scuderi GR. Are 20% of patients actually dissatisfied following total knee arthroplasty? A systematic review of the literature. J Arthroplasty. 2023; 38(3): 594-599. doi:10.1016/j.arth.2022.10.011
- Noble PC, Gordon MJ, Weiss JM, et al. Does total knee replacement restore normal knee function? Clin Orthop Relat Res. 2005; (431): 157-165. doi:10.1097/01.blo.0000150130.03519.fb
- Ramkumar PN, Harris JD, Noble PC. Patient-reported outcome measures after total knee arthroplasty: a systematic review. Bone Joint Res. 2015; 4(7): 120-127. doi:10.1302/2046-3758.47.2000380
- Behrend H, Giesinger K, Giesinger JM, et al. The "forgotten joint" as the ultimate goal in joint arthroplasty: validation of a new patient-reported outcome measure. J Arthroplasty. 2012; 27(3): 430-436.e1. doi:10.1016/j.arth.2011.06.035
- Hamilton DF, Loth FL, Giesinger JM, et al. Validation of the English language Forgotten Joint Score-12 as an outcome measure for total hip and knee arthroplasty in a British population. Bone Joint J. 2017; 99-B(2): 218-224. doi:10.1302/0301-620X.99B2.BJJ-2016-0606.R1
- Thomsen MG, Latifi R, Kallemose T, et al. Good validity and reliability of the forgotten joint score in evaluating the outcome of total knee arthroplasty. Acta Orthop. 2016; 87(3): 280-285. doi:10.3109/17453674.2016.1156934
- Jaeschke R, Singer J, Guyatt GH. Measurement of health status. Ascertaining the minimal clinically important difference. Control Clin Trials. 1989; 10(4): 407-415. doi:10.1016/0197-2456(89)90005-6
- Clement ND, Scott CEH, Hamilton DF, et al. Meaningful values in the Forgotten Joint Score after total knee arthroplasty: minimal clinically important difference, minimal important and detectable changes, and patient-acceptable symptom state. Bone Joint J. 2021; 103-B(5): 846-854. doi:10.1302/0301-620X.103B5.BJJ-2020-0396.R1
- Mazzucchelli L, Deledda D, Rosso F, et al. Cruciate retaining and cruciate substituting ultra-congruent insert. Ann Transl Med. 2016; 4(1): 2. doi:10.3978/j.issn.2305-5839.2015.12.52
- Fritzsche H, Beyer F, Postler A, et al. Different intraoperative kinematics, stability, and range of motion between cruciate-substituting ultracongruent and posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2018; 26(5): 1465-1470. doi:10.1007/s00167-017-4427-8
- Pathak K, Batra S, Sahu A, et al. Ultra-Congruent versus Cruciate-Retaining Inserts in Bilateral Simultaneous Total Knee Arthroplasty: A Prospective Randomized Controlled Trial. J Arthroplasty. 2026; S0883-5403(26)00114-2. doi:10.1016/j.arth.2026.02.003
- Kurina SJ, Higgins JD, Turkmani A, et al. Comparing Patient Preference for Highly-Congruent versus Cruciate-Retaining Inserts in Bilateral Knee Arthroplasties. J Arthroplasty. 2025; 40(9): 2316-2319. doi:10.1016/j.arth.2025.03.074
- Wenzel AN, Hasan SA, Chaudhry YP, et al. Ultracongruent designs compared to posterior-stabilized and cruciate-retaining tibial inserts - what does the evidence tell us? A systematic review and meta-analysis. J Arthroplasty. 2023; 38(12): 2739-2749.e7. doi:10.1016/j.arth.2023.05.064
- Dalton P, Holder C, Rainbird S, et al. Survivorship comparisons of ultracongruent, cruciate-retaining and posterior-stabilized tibial inserts using a single knee system design: results from the Australian Orthopaedic Association National Joint Replacement Registry. J Arthroplasty. 2022; 37(3): 468-475. doi:10.1016/j.arth.2021.11.001
- Law JI, Hurst JM, Morris MJ, et al. Midterm outcomes and survivorship of anterior stabilized versus cruciate retaining bearing in primary total knee arthroplasty. J Arthroplasty. 2021; 36(3): 998-1002. doi:10.1016/j.arth.2020.09.053
- Standifird TW, Cates HE, Zhang S. Stair ambulation biomechanics following total knee arthroplasty: a systematic review. J Arthroplasty. 2014; 29(9): 1857-1862. doi:10.1016/j.arth.2014.03.040
- Wang YQ, Qu GB, Yang JF. Impact of preoperative balance training on postoperative functional recovery of patients after total knee arthroplasty: a systematic review and meta-analysis. Eur Rev Med Pharmacol Sci. 2024; 28(8): 3154-3164. doi:10.26355/eurrev_202404_36031
- Christen B, Heesterbeek P, Wymenga A, et al. Posterior cruciate ligament balancing in total knee replacement: the quantitative relationship between tightness of the flexion gap and tibial translation. J Bone Joint Surg Br. 2007; 89(8): 1046-1050. doi:10.1302/0301-620X.89B8.18976
- Heesterbeek P, Keijsers N, Jacobs W, et al. Posterior cruciate ligament recruitment affects antero-posterior translation during flexion gap distraction in total knee replacement. Acta Orthop. 2010; 81(4): 471-477. doi:10.3109/17453674.2010.501743
- Steinbruck A, Woiczinski M, Weber P, et al. Posterior cruciate ligament balancing in total knee arthroplasty: a numerical study with a dynamic force-controlled knee model. Biomed Eng Online. 2014; 13: 91. doi:10.1186/1475-925X-13-91
- Chakrabarty G, Vashishtha M, Leeder D. Polyethylene in knee arthroplasty: a review. J Clin Orthop Trauma. 2015; 6(2): 108-112. doi:10.1016/j.jcot.2015.01.096
- Hodrick JT, Severson EP, McAlister DS, et al. Highly crosslinked polyethylene is safe for use in total knee arthroplasty. Clin Orthop Relat Res. 2008; 466(11): 2806-2812. doi:10.1007/s11999-008-0472-4
- Prentice HA, Chan PH, Fasig BH, et al. Highly Crosslinked Polyethylene Is Associated with a Lower Revision Risk Out to 20-Year Follow-Up Versus Conventional Polyethylene in Total Knee Arthroplasty. J Arthroplasty. 2026; 41(3): 758-764.e2. PMID: 40645533. doi:10.1016/j.arth.2025.07.005
- Gianzina E, Kalinterakis G, Delis S, et al. Evaluation of gait recovery after total knee arthroplasty using wearable inertial sensors: a systematic review. Knee. 2023; 41: 190-203. doi:10.1016/j.knee.2023.01.006
- Small SR, Bullock GS, Khalid S, et al. Current clinical utilisation of wearable motion sensors for the assessment of outcome following knee arthroplasty: a scoping review. BMJ Open. 2019; 9(12): e033832. doi:10.1136/bmjopen-2019-033832
- Strait AV, Wilson EJ, Ho H, et al. A comparison of medial-congruent, ultracongruent, and cruciate-retaining bearings using a single cruciate-retaining total knee design. Arthroplast Today. 2025; 32: 101632. doi:10.1016/j.artd.2025.101632
- Lutzner J, Beyer F, Lutzner C, et al. Ultracongruent insert design is a safe alternative to posterior cruciate-substituting total knee arthroplasty: 5-year results of a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc. 2022; 30(9): 3000-3006. doi:10.1007/s00167-021-06545-4
- Macedo F, Lucas J, Cunha P, et al. No difference in patient-reported outcomes or range of motion between ultracongruent and posterior stabilized total knee arthroplasty: a randomized controlled trial. J Exp Orthop. 2024; 11(4): e70043. doi:10.1002/jeo2.70043